We’d Gladly Machine the Plate Between Your Coolant and the GPU
Mention Sealing Surfaces and Our Engineers Lean In
A few thousandths of flatness on a cold plate, a stray burr near a quick connect or a hose guide that misses its bend radius can send a rack back through validation. And the drawings rarely sit still long enough for a production supplier to get comfortable.
Send us the revised print, even if it changed again last week, and our engineers will review it for flatness, burrs, sealing surfaces and cleanliness before we quote. Then we’ll build it, inspect it and keep the record tied to that revision.
-
Direct-to-chip cooling: Cold-plate blanks, thermal plates, lids, retention brackets and inspection nests.
-
Rack manifolds and CDUs: Manifold blocks, CDU brackets, hose guides, quick-connect guards and spill trays.
-
Rear-door and immersion systems: Hinge plates, door frames, airflow baffles, lid frames and server carriers.
-
Leak management and deployment: Leak trays, drip shields, sensor brackets, flow-test fixtures and install kits.
Getting a Cold Plate Perfectly Flat Never Gets Old for Us
Thermal programs usually end up choosing between a quick-turn shop that’ll machine a cold plate by Friday with little paperwork and a production supplier that documents everything but wants a frozen drawing. Your hardware needs both while the design is still moving.
Here’s how we give you both:
-
Domestic manufacturing: Cold plates, manifold hardware and kits built across 10 U.S. locations, with lot traceability.
-
DFM, DFQ and DFE review before the quote: We flag flatness, burr, thread and material-compatibility risks, then suggest changes.
-
30+ manufacturing technologies: CNC, precision turning, sheet metal, photochemical machining, additive and molding under one partner.
-
White-glove service: A named team that knows your revision history and answers when the next ECO lands.
Your Data Center & Energy Infrastructure Team
Karl Satrum
Jacob Delury
Bobby Youssefi
ICT & Energy Application Expertise
We have years of experience delivering high-quality parts for data center racks, thermal management and energy storage applications.
-
Server rack and enclosure systems
-
Manifolds, port blocks and brackets for server cooling systems
-
Pump, heat exchanger and cold-plate adjacent metalwork for cooling systems
-
Power distribution, busways and intelligent PDUs
-
Power module chassis and mounts
-
Switchgear and control cabinet enclosures
-
Busbar supports and structural frames
-
BESS enclosures for energy storage
-
Inverter and PCS cabinets
Data Centers: How is Liquid Cooling Altering Cabinet Design?
AI data center builders are packing more blade servers into less space. That is pushing rack designs from air cooling to liquid cooling. Use our interactive infographic to see which mechanical components, mounting, routing, access and assembly must change and what to check before you release the enclosure design.
Direct-to-Chip Cooling Gets Interesting at the Sealing Surface
Direct-to-chip is becoming the default for dense AI racks, and every new GPU generation reshuffles plate geometry, mounting and inlet positions. We’d enjoy machining your cold-plate blanks, thermal plates, lids, retention brackets, flow-channel test coupons and inspection nests.
Every Rack Generation Moves the Manifold a Little
Manifold positions, CDU mounting, hose bend radii and quick-connect locations keep shifting as rack architectures mature, and each move ripples through the loop. We’d welcome the manifold blocks, CDU brackets, hose guides, quick-connect guards, valve brackets and spill trays.
Every Data Hall Has Its Own Rack Datum
Rear-door heat exchangers let operators raise rack density without a full liquid conversion, but hinge clearances and service access change from hall to hall. We’d happily make mounting brackets, hinge plates, door frames, fan guards, airflow baffles and retrofit kits.
In an Immersion Tank, Every Burr Eventually Gets Noticed
Immersion is a more selective path than direct-to-chip, and it raises the bar on fluid compatibility, low-burr edges and safe, ergonomic service. We’d be keen to build tank brackets, lid frames, server carriers, lift adapters, service carts and sample-port guards.
The Cheapest Parts Protect the Most Expensive Hardware
Liquid cooling puts fluid next to the most valuable compute, so parts that guide hoses and catch drips matter more than their price suggests. We’d like to make leak trays, drip shields, sensor brackets, connector covers and drain guides.
Power and Cooling are Fighting for the Same Space
Denser racks put power shelves, busbars and coolant lines inches apart, and the hardware between them has very little room to work. We’re eager to build insulating shields, terminal covers, power-shelf brackets, standoffs and connector guards to your spec.
Flow-Test Fixtures Are Some of Our Favorite Projects
Thermal programs have to assemble, pressure-test, ship and install repeatable hardware on data center schedules, so fixtures and kits often set the pace. We’d be happy to build leak, pressure and flow-test fixtures, hose-routing gauges, inspection nests and install kits.
1,000+
5,000+
30+
ISO 9001:2015
Fathom Edgeworks: Built to Support Data Center Thermal Programs
Our global sourcing solution, Fathom Edgeworks, gives data center thermal management manufacturers access to an extended network of sourcing options through one accountable Fathom team.
Our domestic manufacturing capabilities are built to support liquid-cooling programs, from prototyping through bridge production to deployment-scale volumes. That includes everything from precision thermal and structural components to rugged enclosures and cable-management hardware, all matched to the right source.
And when cost or timing matters more than staying domestic, overseas injection molding through our global partner network is available as a lower-cost option for authorized, non-sensitive repeat parts.
Use our instant quoting tool to see what Edgeworks can make for you.
What Every Data Center Thermal Management Engineer, Program Manager & Procurement Manager Gets With Fathom
Hardware Around the Whole Loop
Cold plates, manifold supports, trays, shields, covers and fixtures on one purchase order.
10 U.S. Locations
Domestic capacity across processes, with one team keeping every revision straight.
DFM Before the Quote
Flatness, burrs, sealing surfaces and material compatibility reviewed before you commit.
Built for Fast ECO Cycles
Additive fit-checks and quick CNC turns keep parts coming while designs move.
Prototype to Bridge to Deployment
One team carries your parts from first fit-check through every deployment wave.
Specialty Processes In House
Photochemical shims, precision turning, urethane casting and finishing alongside CNC and sheet metal.
Which Thermal Part Is Giving Your Team the Most Trouble Right Now?
Let’s start a short technical conversation about the hardware around your coolant loop, whether it’s still on a validation bench or already headed to a data hall.
Bring a print, a problem or a rough idea. For example:
- A cold-plate or manifold interface that keeps changing while the rack build has to stabilize.
- Flatness, burr, finish or cleanliness questions on hardware headed for a coolant loop.
- Leak, pressure and flow-test fixtures your assembly line was never scoped to build.
- Rear-door retrofit kits and service spares for data halls that are already energizing.
You’ll hear back from an engineer who can tell you what’s makeable, what it will take and what to change before it turns into a first-article problem.